POWER PROTECTION
IMPORTANT SAFETY INSTRUCTIONS
WARNING: Do not attempt to service this product yourself except to
replace the battery. Opening or removing the cover may expose you to
dangerous voltages, even when the AC cord is disconnected from the
electrical outlet. Refer all servicing to qualified service personnel.
1. SAVE THESE INSTRUCTIONS. THIS MANUAL CONTAINS
IMPORTANT SAFETY INSTRUCTIONS. Read all safety and operating
instructions before operating the Uninterruptible Power System (UPS).
Adhere to all warnings on the unit and in this manual. Follow all
operating and user instructions.
2. This product is designed for Commercial/Industrial use only. It is not
intended for use with life support and other designated “critical” devices.
Maximum load must not exceed that shown on the UPS rating label. If
uncertain, consult your dealer. See Limited Warranty.
3. When replacing the batteries, use the appropriate Liebert-Approved
Replacement Battery Kit. Proper disposal of batteries is required. Refer
to your local laws and regulations for disposal requirements.
4. Always turn off the UPS and unplug it before starting the battery
replacement procedure. To replace batteries, refer to the battery
replacement procedure. If you feel unqualified to replace the batteries,
do not open the battery door. Refer all servicing to qualified service
personnel.
5. CAUTION: Do not open or mutilate the batteries. Released electrolyte is
harmful to skin and eyes and may be toxic.
6. The mains supply socket or means of isolation must be within 2 metres
of the equipment and accessible to the operator. The UPS is designed
for data processing equipment.
7. The UPS comes with two output power leads with moulded connectors.
Do not modify the output power leads. Consult dealer if connector does
not match the load socket. UPS must be earthed at all times while in
use. Turn UPS off before unplugging it, or the safety earth will be
removed.
8. The PowerSure Interactive models 700 VA, 1000 VA, and 1400 VA are
not supplied with an input power lead for connection to the mains supply
socket. Use the input mains supply power lead from your data
processing equipment to connect the UPS to the mains supply. For the
2200 VA model, use the supplied 16 ampere rated input mains supply
leads. For UK supply systems, consult a qualified electrician to connect
the lead supplied for the 2200 VA model to the mains supply. Note
caution on following page.
USER MANUAL
English
700-2200 VA
230 V
PowerSure™ Interactive
R
2
Vue de la page 0
1 2 3 4 5 6 ... 13 14

Résumé du contenu

Page 1 - USER MANUAL

POWER PROTECTION IMPORTANT SAFETY INSTRUCTIONS WARNING: Do not attempt to service this product yourself except to replace the battery. Opening or

Page 2 - GLOSSARY OF SYMBOLS

RACKMOUNT BATTERY REPLACEMENT CAUTION- A battery can present a risk of electrical shock and high short circuit current. The following precautions s

Page 3 - MINI-TOWER INSTALLATION

TROUBLESHOOTING The information below indicates various symptoms a user may encounter in the event the PowerSure™ Interactive UPS develops a problem

Page 4 - RACKMOUNT INSTALLATION

POWERSURE™ INTERACTIVE TYPICAL BATTERY DISCHARGE CURVES (Discharge times are at 25° C ambient) 0 25 50 75 100020406080Percent LoadRun Time (Mins)0 2

Page 5 - CONTROLS AND INDICATORS

MINI-TOWER SPECIFICATIONS Model Number PS700MT-230 PS1000MT-230 PS1400MT-230 PS2200MT-230 Model Rating VA/W 700 / 450 1000 / 670 1400 / 950 2

Page 6 - 1000/1400 Model

1050 Dearborn Drive Columbus, OH 43229 614-888-0246 Technical Support U.S.A...

Page 7 - (Flashes every second)

CAUTION: The UPS and connected load total earth leakage current must not exceed 3.5 milliamperes. If the connected load earth leakage current is li

Page 8 - MAINTENANCE

MAJOR COMPONENTS TRANSIENT VOLTAGE SURGE SUPPRESSION (TVSS) AND EMI/RFI FILTERS These UPS components provide surge protection and filter electromagn

Page 9

The wires in the mains lead are colored with the following code: Green and Yellow = Earth Blue = Neutral Brown = Live As the color of the wires i

Page 10

The blue wire must be connected to the terminal which is marked with the letter “N” or colored black. The brown wire must be connected to the termin

Page 11 - (flashes every second)

MINI-TOWER POWERSURE™ INTERACTIVE RACKMOUNT POWERSURE™ INTERACTIVE Fault IndicatorLoad/BatteryLevel IndicatorsAlarm Silence/Battery Test ButtonOn

Page 12 - BATTERY DISCHARGE CURVES

OPERATION NORMAL MODE OPERATION During normal operation, mains power provides energy to the UPS. The filters and the power conditioning circuit pro

Page 13 - RACKMOUNT SPECIFICATIONS

COMMUNICATIONS INTERFACE PORT The PowerSure™ Interactive UPS contains a standard DB-9 receptacle located on the rear of the UPS unit. Several signa

Page 14 - LIMITED WARRANTY

MINI-TOWER BATTERY REPLACEMENT CAUTION- A battery can present a risk of electrical shock and high short circuit current. The following precautions

Commentaires sur ces manuels

Pas de commentaire